3.2. Apply Power to the CMSConnect the CMS to an appropriate power source. Press the Power Switch ON. The ON LEDshould light, and the RDY LED shoul

Página 3 - Table of Contents

Perform the following procedure to access the CMS Command Mode, explore basic features,and check for proper operation.Start your communications progra

Página 4

/T Reset Network Interface +-----------------------+/D, /E, /I, /T Commands: Add /Y to bypass "Sure (Y/N)?"Figure 3.1: Th

Página 5 - List of Figures

create a connection between two other ports.To connect Port 2 to Port 3, type /C 2 3 [Enter].i. While Ports 2 and 3 are connected, Port 1 will still

Página 6 - 1. Introduction

CAUTION: This device should only be operated with the type of power sourceindicated on the instrument nameplate. If you are not sure of the type of p

Página 7 - 2. Unit Description

when communicating with the CMS. This will ensure access to command functions, even if theunit is initialized to default parameters.Note:If the Option

Página 8 - 2.2. Back Panel

Up Down XON/XOFFDown Up BothUp Up None* = Factory Setting4.2.3. Default Response Message Format (Sw6)When commands are invoked, the CMS can respond

Página 9 - 3. Getting Started

4.4. Connecting Devices to the CMSAccess the Command Mode.1. Determine which port will be used for connection to the new device (e.g. Port 3).2. C

Página 10 - 3.3. System SetUp Ports

Figure 4.2: CMS Application Example (Not to Scale)The example in Figure 4.2 shows one of many possible installation configurations for the CMS.In t

Página 11

configuration, connect to any port, or review unit status. Users are only allowed to reviewstatus and connect to the ports allowed by their Port Passw

Página 12

Warnings and Cautions:No Serviceable Parts Inside; Authorized Service PersonnelOnlyDo not attempt to repair or service this device yourself. Internal

Página 13 - 4. Hardware Installation

Modem Access: To access the command mode via modem, proceed as follows:Dial the number for the external modem connected to the CMS.i. If you have de

Página 14

5.3. Password FunctionsThe CMS features two different types of passwords; the Supervisor Password and the Port(User) Passwords. The Supervisor Passw

Página 15

Supervisor Level Commands. In this case, the only way to access theSupervisor Mode, is to reinitialize the CMS to default values as described inSectio

Página 16

display the System Parameters Menu.Site ID Message: (Up to 32 characters; Default = undefined) Type 1 and press [Enter],the Site I.D. Prompt will appe

Página 17 - 4.5. Application Example

To exit a menu or prompt without changing its current value, press [Esc].● Passwords and port names are case sensitive. When defining passwords and

Página 18

Parameters selected via these menus will stay in effect until the unit is initialized or the /Pcommand is used to reconfigure the port. After initiali

Página 19 - 5. Configuration

Note: The Port Password is not displayed by the Port Parameters menu. When thePort Password has been defined, the field for this item will read "

Página 20 - 5.2. System SetUp Ports

Enter: "<" Previous Port, ">" Next Port, <ESC> Exit ...Figure 5.2: Port Configuration Menu (Modem Mod

Página 21 - 5.3. Password Functions

When a Resident Connection is initiated, the CMS will send a message which liststhe connected ports, and displays the one character or three character

Página 22

contact your network administrator for appropriate settings, and then assign parameters asdescribed in this section.NETWORK PARAMETERS 1. IP Address:

Página 23 - 5.5. Port Configuration

When mounting the unit in an enclosed rack with a ventilation fan at the top of the rack,note that excessive heat generated by devices at the bottom o

Página 24

disconnect from a second port (Resident Disconnect). When defining the LogofffCharacter, note the following:The default Logoff Character is "+&qu

Página 25

Accept Break: Determines whether the port will accept breaks received from theattached device, and pass them along to a connected port. When enabled,

Página 26

Masks are listed in order of ascending priority; Mask 1 has the lowest priority, andMask 5 has the highest priority.b. Masks have a cumulative effect

Página 27 - <ESC> Exit

When using the wild card address "255.255.255.255" to block access by allIP addresses, make certain that at least one higher priority mask p

Página 28

(Note: Ports 1 & 2 will NOT have restricted values changed.)Enter: Parameter # <CR> to define parameter value to copy to allports, -&l

Página 29

RS-232 ports. To display the Port Status Screen, access the command mode and type /S [Enter], the screen will appear as shown in Figure 6.1.Although b

Página 30

currently connected to the CMS Network Port.Mode: The user-selected Port Mode. This column will read Any (Any-to-Any), Modem,Passive, or Buffer, depe

Página 31

Port: The Port Number. Note that if this column contains a plus sign (+), this indicatesthat the port will be allowed to access the Supervisor Mode i

Página 32

NETWORK STATUSLAN STATUSNIC Installed: YesMAC Address: 00-40-05-6d-a3-edTELNET PORT STATUSName: (undefined)Telnet Connection

Página 33

PORT PARAMETERS #03: 1. Port Name: (undefined) 2. Password: (undefined) 3. Baud Rate: 9600 4. Bits/Parity:

Página 34 - 6. The Status Screens

4.1.2. DC Powered Units 4.2. Configure Option Switches4.2.1. Default Baud Rate (Sw1, Sw2, Sw3) 4.2.2. Default Handshake (Sw4, Sw5) 4.

Página 35

(User) password, the /W command will only display the Sequence Disconnect,Logoff Character, and the status of the Accept Break item.7. Operation7.1.

Página 36

Invoke the /C command to connect the desired ports.Resident Connect: To connect your resident port to another port, type /C xx [Enter]. Where xx is

Página 37

Character Format (for more information, please refer to Section 5.5.3.):Three Characters (Default): Uses the format "[Enter]LLL[Enter]", whe

Página 38

Network Port: To configure the Timeout Feature for the Network Port, invoke the/N command to display the Network Port Configuration Menu as described

Página 39

Ports 1 and 2 are Modem Mode ports, and modems are installed at both ports. Port 1 isnamed "MODEM1" and Port 2 is named "MODEM2".

Página 40 - 7. Operation

Buffer Mode Ports cannot access the Command Mode.● In order to ensure supervisor access to important command functions, theBuffer Mode is not availa

Página 41

7.3.2. Port BuffersThe Status Screen lists the amount of Buffer Memory currently used by each port. The CMSuses buffer memory in two different ways,

Página 42

8. Saving and Restoring ConfigurationParametersAfter the CMS has been properly configured, parameters can be downloaded and saved as anASCII text fi

Página 43

name and directory path.Your terminal emulation program will send the ASCII text file to the CMS. When theterminal program is finished with the upload

Página 44 - 7.3. Buffer Mode

Note: When the upgrade is performed via the Network Port, the CMS will notdefault the IP Address, Subnet Mask, or Gateway Address. This allows the te

Página 45

7.1.1.2. Disconnecting Ports 7.1.2. Defining Hunt Groups 7.2. Passive Mode❍ 7.3. Buffer Mode7.3.1. Reading Data from Buffer Mode Por

Página 46 - 7.4. Modem Mode

Slash Character: Most CMS commands begin with the Slash Character (/).● Apply Command to All Ports: When the asterisk character is entered as the

Página 47 - Parameters

The table below summarizes the various response messages for both the Terse and Verbosemodes.Terse Verbose0 OK0 RAM Test Passed1 Connected *2 Busy3 Di

Página 48 - 9. Upgrading CMS Firmware

Display Port Status/S[P] [Enter]X (1) (2) X (1)Display Port Diagnostics/SD [Enter]X (1) X (1)Display Network Status/SN [Enter]X Display PortParam

Página 49 - 10. Command Reference Guide

10.4. Command SetThis Section provides more detailed information on all CMS commands, sorted alphabetically byname. [Enter] Enter Command ModeIn o

Página 50 - 10.2. Command Response

Establishes a bi-directional connection between two ports. For more information and commandline examples, please refer to Section 7.1. There are two d

Página 51 - 10.3. Command Summary

Resident Disconnect Sequence or wait for the Timeout Period to elapse (if enabled).Availability: Supervisor OnlyFormat: /D[/Y] <x> [x] [Enter

Página 52

access to command mode. For more information, refer to Section 5.4.Note: Make certain to record your Supervisor Password for future reference. If the

Página 53 - 10.4. Command Set

Format: /J [Enter]Response: Displays Site I.D. Message /N Set Network Port ParametersDisplays a menu which is used to define communication parame

Página 54

/SD Display Port DiagnosticsProvides more detailed information regarding the operational status of each port. Note that inUser Mode, this screen wil

Página 55

/UF Upgrade FirmwareWhen new versions of the CMS operating firmware become available, this command is used toupdate the existing firmware as describ

Página 56

5.4. IP Security Menu● 5.5. The Copy Port Parameters Menu● 6.1. The Port Status Screen (Supervisor Mode, Defaults Shown)● 6.2. The Port

Página 57

Availability: Supervisor / UserFormat: /X [Enter]Response: DisconnectedAppendix A. RS232 Port Interface Figure A.1: RS232 Port InterfaceDCD an

Página 58

RS232 Port Interface: 16 RS232 serial inputs use DB9 connectors configured as DTEports.● Network Interface: 10Base-T Ethernet, RJ45● Coding: As

Página 59

Trademark and Copyright InformationWTI and Western Telematic are trademarks of Western Telematic Inc.. All other product namesmentioned in this publi

Página 60 - Appendix B. Specifications

Once you have configured the CMS to fit your application, parameters and options can be savedto an ASCII text file on your PC. This allows you to quic

Página 61

button, wait for the Port LEDs to flash, and then release the SET button.Note:During initialization, all port LEDs will flash ON three times.● Durin

Página 62

Ports 1 and 2 are System Setup Ports, which are used for communication duringset-up and configuration. Note that Supervisor Level command access canno